If you've ever started a business then you'll know that the installation of a fire alarm system should be undertaken in accordance with British Standard 5839 fire alarm regulations and should only ever be undertaken by a qualified installer.
Here's a taste of what you're up against...
Fire Alarm Installations In Public Buildings
There are a considerable number of regulations involved and in addition, there may be extra requirements of a local authority or fire authority.
Just to provide some idea of the fire alarm regulations complexities, we list here a sample of the requirements of BS5839.
To begin with, an AFD (Automatic Fire Detection) system may be designed to protect property or to protect human life. In order to protect property, an AFD may be installed either in all areas, or in specifically defined areas.
To protect life, the AFD may be installed in all areas, in defined areas at higher risk of fire, in escape routes and rooms leading to them, in corridors and stairways, or in areas where there is a specific fire risk. In addition, a manual fire alarm may also be required in certain circumstances.
Fire Alarm Sound Levels
The volume of a sounder device should be a minimum of 65 decibels, or 5db above any background noise if such noise continues for more than half a minute.
For instance, consider fire alarm regulations in a factory. Machinery may be operating all day so that needs to be taken into account. The maximum sound level should not exceed 120db. Cabling for sounders should be such that, in case of a fault, at least one sounder will operate in the area of the control panel.


The maximum floor area of any individual zone is 2,000 square metres and a person searching for the source of a fire must not have to travel more than 60 metres from the entry point to find it. Equally, a person using an escape route should not have to travel more than 45 metres to reach a manual call point.
The centre of a manual call point should be positioned 1.4 metres from the floor, unless the first person likely to raise the alarm may be wheelchair bound. Fire alarm regulations say that visual alarms, such as flashing lights, should be mounted at a minimum of 2.1 metres from the floor and in a position where it is likely that they would attract attention.
Further Regulations For Fire Alarm Installations
In areas where people sleep, the minimum volume of a sounder device should be 75 db at the head of the bed and, in buildings where there may be people with impaired hearing, both audio and visual alarms should be considered.
Loss of sound occurs through doors. In the case of a normal door, around 20 db will be lost and in the case of fire doors, around 30 db will be lost. It is suggested that, unless a sounder is sited in a bedroom, it is not likely that the minimum level of 75 db will be reached.
Fire alarm regulations also state that a smoke or heat detector device should not be mounted within 500 mm of an obstruction. If the top of a solid partition is less than 300 mm from the ceiling, it should be treated as a wall. Similarly, a beam on a ceiling that is deeper than 10% of the ceiling height should also be treated as a wall.
This is just a sample
The foregoing is just a sample of some of the requirements. There are many others concerning lift shafts, stairways, smoke detectors, heat detectors and so on. However, it does give some idea of all the things that need to be taken into consideration when designing a fire alarm installation and why it is only ever a job for the trained professional who is BAFE registered.
How a fire alarm system is installed
Installing a fire alarm in a public building happens in a set order. The BAFE scheme for fire alarms (SP203-1) certifies companies separately for design, installation, commissioning and maintenance, which shows that each stage is a distinct job. Here is how the stages run from start to finish.
- Fire risk assessment. The person in charge of the building is known as the "responsible person". This is the employer, owner, landlord or occupier. GOV.UK says they must "carry out a fire risk assessment of the premises and review it regularly". The findings help decide what protection the building needs.
- Design. The designer decides where the detectors, sounders and manual call points should go, and whether the system should protect people, property or both. BAFE says this stage is carried out by "a designated expert" working to the relevant codes of practice and standards.
- Installation. BAFE says installation is "performed by competent technicians working to the approved design". They fit the control panel, detectors, sounders, call points and cabling to that design.
- Commissioning and testing. Once the system is fitted, it is tested to check it works as the standard and the specification require. BAFE describes this as "detailed checks to ensure the system is safe and ready to use". It is worth agreeing who will commission the system before installation work starts.
- Handover. At the end of commissioning, the installer should confirm that all the relevant documents have been given to you as the user.
- Maintenance. A fire alarm needs regular inspections by technicians who understand the British Standards. GOV.UK says the responsible person must "put in place, and maintain, appropriate fire safety measures".
The British Standard for these systems, BS 5839-1, was updated in April 2025 and replaced the 2017 edition. Among other changes, it adds clearer guidance on extending and upgrading existing fire alarm systems.
Spy Alarms helps businesses and public buildings across London and Kent with fire alarm systems. To find out how we can help, see our fire alarm installation service.


Don't leave it to chance - Ensure your protected from fire with our help


Thousands of businesses across London and Kent rely on us to ensure their property, people and assets are safe from the threat of fire. Our methodical planning and in-depth installations have helped to ensure businesses are not only safe from fire, but also complying to the necessary legislation for their industry.